RIGOL User’s Guide MSO1000Z/DS1000Z Series Digital Oscilloscope Jul. 2014 RIGOL Technologies, Inc.
RIGOL VIII MSO1000Z/DS1000Z User’s Guide Measurement Category Measurement Category MSO1000Z/DS1000Z series digital oscilloscopes can make measure
RIGOL Chapter 5 To Trigger the Oscilloscope 5-28 MSO1000Z/DS1000Z User’s Guide Setup: the oscilloscope triggers when the setup time is less than
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-29 Nth Edge Trigger (Option) Trigger on the nth edge that appears a
RIGOL Chapter 5 To Trigger the Oscilloscope 5-30 MSO1000Z/DS1000Z User’s Guide Idle Time: Press Idle to set the idle time before the edge counting i
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-31 RS232 Trigger (Option) RS232 bus is a serial communication mode
RIGOL Chapter 5 To Trigger the Oscilloscope 5-32 MSO1000Z/DS1000Z User’s Guide --press Data Bits to select “5 bits”, “6 bits”, “7 bits” or “8 bits”;
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-33 I2C Trigger (Option) I2C is a 2-wire serial bus used to connect
RIGOL Chapter 5 To Trigger the Oscilloscope 5-34 MSO1000Z/DS1000Z User’s Guide occurs, the oscilloscope will trigger on the read/write bit. After th
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-35 SPI Trigger (Option) In SPI trigger, after the CS or timeout con
RIGOL Chapter 5 To Trigger the Oscilloscope 5-36 MSO1000Z/DS1000Z User’s Guide “ ” (high level is valid) or “ ” (low level is valid). Timeout: th
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-37 Trigger Output Connector The trigger output connector ([Trigger
RIGOL MSO1000Z/DS1000Z User’s Guide IX Ventilation Requirement This oscilloscope uses fan to force cooling. Please make sure that the air inta
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-1 Chapter 6 MATH and Measurement MSO1000Z/DS1000Z can make math operation,
RIGOL Chapter 6 MATH and Measurement 6-2 MSO1000Z/DS1000Z User’s Guide Math Operation MSO1000Z/DS1000Z can realize various math operations, inclu
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-3 You can also use HORIZONTAL POSITION and HORIZONTAL SCALE to adju
RIGOL Chapter 6 MATH and Measurement 6-4 MSO1000Z/DS1000Z User’s Guide CH4 or fx (please refer to the introduction in “Fx Operation”)). Press O
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-5 ― Press Invert to enable or disable the inverted display function of the
RIGOL Chapter 6 MATH and Measurement 6-6 MSO1000Z/DS1000Z User’s Guide FFT FFT (Fast Fourier Transform) is used to transform time domain signals
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-7 waveform corresponding to the horizontal center of the screen. 4. Horiz
RIGOL Chapter 6 MATH and Measurement 6-8 MSO1000Z/DS1000Z User’s Guide of signal. require to accurately measurement. Triangle Better frequency res
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-9 “AND” Operation Perform logic “AND” operation on the waveform voltage va
RIGOL X MSO1000Z/DS1000Z User’s Guide Working Environment Temperature Operating: 0℃ to +50℃ Non-operating: -40℃ to +70℃ Humidity 0℃ to +30℃: ≤95%
RIGOL Chapter 6 MATH and Measurement 6-10 MSO1000Z/DS1000Z User’s Guide “Fx Operation”). Note: Smooth is grayed out and disabled. It is only avail
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-11 0.96 Div. ― Press Auto Scale to enable or disable the auto scale functi
RIGOL Chapter 6 MATH and Measurement 6-12 MSO1000Z/DS1000Z User’s Guide disable waveform invert, etc. ― Press Start and use to set the start po
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-13 Press Options to set the start and end points of the operation result
RIGOL Chapter 6 MATH and Measurement 6-14 MSO1000Z/DS1000Z User’s Guide ― Press fx Operator, fx A and fx B to set the operator and signal sources
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-15 Tip Because the differential operation is very sensitive to noise, you c
RIGOL Chapter 6 MATH and Measurement 6-16 MSO1000Z/DS1000Z User’s Guide Lg (Use 10 as the Base) Calculate the logarithm of the selected source (u
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-17 Press Scale Reset to adjust the vertical scale of the operation resul
RIGOL Chapter 6 MATH and Measurement 6-18 MSO1000Z/DS1000Z User’s Guide “Fx Operation”). Note: Sens. and Smooth are grayed out and disabled. Sens.
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-19 Fx Operation MSO1000Z/DS1000Z supports the fx operation function which
RIGOL MSO1000Z/DS1000Z User’s Guide XI Pollution degree 2: Normally only dry, non-conductive pollution occurs. Occasionally a temporary conduct
RIGOL Chapter 6 MATH and Measurement 6-20 MSO1000Z/DS1000Z User’s Guide Auto Measurement MSO1000Z/DS1000Z provides auto measurements of 33 wavefo
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-21 One-key Measurement of 33 Parameters Press MENU at the left of the scre
RIGOL Chapter 6 MATH and Measurement 6-22 MSO1000Z/DS1000Z User’s Guide Time Parameters Figure 6-3 Time Parameters 1. Period: defin
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-23 Delay and Phase Source 1Source 2PeriodDelay Figure 6-4 Delay and Phase
RIGOL Chapter 6 MATH and Measurement 6-24 MSO1000Z/DS1000Z User’s Guide Voltage Parameters Figure 6-5 Voltage Parameters 1.
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-25 Wherein, ixis the ith point being measured, nis the number of points bei
RIGOL Chapter 6 MATH and Measurement 6-26 MSO1000Z/DS1000Z User’s Guide Frequency Counter Measurement The hardware frequency counter supplied wit
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-27 Press Max and use to set the upper limit of the measurement. Reduci
RIGOL Chapter 6 MATH and Measurement 6-28 MSO1000Z/DS1000Z User’s Guide All Measurement All measurement could measure all the time and voltage pa
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-29 Statistic Function Make statistic and display the current, average, min
RIGOL XII MSO1000Z/DS1000Z User’s Guide General Care and Cleaning General Care: Do not store or leave the instrument at places where the instrumen
RIGOL Chapter 6 MATH and Measurement 6-30 MSO1000Z/DS1000Z User’s Guide Table Measurement Result Display Type The measurement results can be d
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-31 Manual Mode In this mode, a pair of cursors will appear. You can adjust
RIGOL Chapter 6 MATH and Measurement 6-32 MSO1000Z/DS1000Z User’s Guide Its unit is the same as that of the current signal source. BX-AX: the h
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-33 adjustment and the adjustable range is limited within the screen. Adj
RIGOL Chapter 6 MATH and Measurement 6-34 MSO1000Z/DS1000Z User’s Guide Note: ― When the cursor measurement source is LA and the main time base
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-35 Track Mode In this mode, one or two pairs of cursors will appear. You c
RIGOL Chapter 6 MATH and Measurement 6-36 MSO1000Z/DS1000Z User’s Guide A. During the adjustment, the measurement result will change accordingly.
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-1 Auto Mode In this mode, one or more cursors will appear. You can use auto
RIGOL Chapter 6 MATH and Measurement 6-2 MSO1000Z/DS1000Z User’s Guide XY Mode XY mode is only available when the horizontal time base mode is “X
Chapter 6 MATH and Measurement RIGOL MSO1000Z/DS1000Z User’s Guide 6-3 Figure 6-9 XY Cursor Measurement Definition 1. Select Values Press Va
RIGOL MSO1000Z/DS1000Z User’s Guide XIII MSO1000Z/DS1000Z Series Overview MSO1000Z is a mixed signal digital oscilloscope aimed at the embedde
RIGOL Chapter 6 MATH and Measurement 6-4 MSO1000Z/DS1000Z User’s Guide 3. Display Lissajous Legend This oscilloscope provides the lissajous schem
Chapter 7 Digital Channel RIGOL MSO1000Z/DS1000Z User’s Guide 7-1 Chapter 7 Digital Channel MSO1000Z series mixed signal digital oscilloscope pr
RIGOL Chapter 7 Digital Channel 7-2 MSO1000Z/DS1000Z User’s Guide To Select the Digital Channel Press LA to open the logic analysis control menu.
Chapter 7 Digital Channel RIGOL MSO1000Z/DS1000Z User’s Guide 7-3 Note: ― When you have turned off channels D7-D0 at the same time using D7-D
RIGOL Chapter 7 Digital Channel 7-4 MSO1000Z/DS1000Z User’s Guide To Set the Waveform Display Size Press WaveSize to open the waveform size selec
Chapter 7 Digital Channel RIGOL MSO1000Z/DS1000Z User’s Guide 7-5 Press Low Type to open the threshold selection list to select the threshold of
RIGOL Chapter 7 Digital Channel 7-6 MSO1000Z/DS1000Z User’s Guide Digital Channel Delay Calibration When using the oscilloscope for actual measur
Chapter 8 Protocol Decoding RIGOL MSO1000Z/DS1000Z User’s Guide 8-1 Chapter 8 Protocol Decoding Protocol analysis can be used by users to discov
RIGOL Chapter 8 Protocol Decoding 8-2 MSO1000Z/DS1000Z User’s Guide Parallel Decoding Parallel bus consists of clock line and data line. As shown i
Chapter 8 Protocol Decoding RIGOL MSO1000Z/DS1000Z User’s Guide 8-3 In additional, you can also modify the settings of Width, Bit X and CH manua
RIGOL XIV MSO1000Z/DS1000Z User’s Guide Document Overview Main Topics of this Manual: Chapter 1 Quick Start Introduce the preparations before usi
RIGOL Chapter 8 Protocol Decoding 8-4 MSO1000Z/DS1000Z User’s Guide Tip Press MATH Decode Options ASC List, characters, numbers and ASCII table
Chapter 8 Protocol Decoding RIGOL MSO1000Z/DS1000Z User’s Guide 8-5 12. Event Table The event table displays the decoded data and the correspond
RIGOL Chapter 8 Protocol Decoding 8-6 MSO1000Z/DS1000Z User’s Guide RS232 Decoding (Option) RS232 serial bus consists of the transmitting data line
Chapter 8 Protocol Decoding RIGOL MSO1000Z/DS1000Z User’s Guide 8-7 Start Bit: represent when the data starts outputting. Data Bits: represent
RIGOL Chapter 8 Protocol Decoding 8-8 MSO1000Z/DS1000Z User’s Guide Press Data to set the data width of each frame. It can be set to 5, 6, 7 or
Chapter 8 Protocol Decoding RIGOL MSO1000Z/DS1000Z User’s Guide 8-9 Press Format to enable or disable the format display function. When “ON”
RIGOL Chapter 8 Protocol Decoding 8-10 MSO1000Z/DS1000Z User’s Guide Wherein, there are even number of 1 in the 5-bit data 10111 and the check
Chapter 8 Protocol Decoding RIGOL MSO1000Z/DS1000Z User’s Guide 8-11 I2C Decoding (Option) I2C serial bus consists of the clock line (SCLK) and
RIGOL Chapter 8 Protocol Decoding 8-12 MSO1000Z/DS1000Z User’s Guide 7. Event Table The event table displays the decoded data, the corresponding li
Chapter 8 Protocol Decoding RIGOL MSO1000Z/DS1000Z User’s Guide 8-13 9. Address Information during Decoding In I2C bus, the front part of each
RIGOL MSO1000Z/DS1000Z User’s Guide XV Chapter 14 Store and Recall Introduce how to store and recall the measurement result and the setting of
RIGOL Chapter 8 Protocol Decoding 8-14 MSO1000Z/DS1000Z User’s Guide Figure 8-7 I2C Error Expressions during Decoding ACK=1
Chapter 8 Protocol Decoding RIGOL MSO1000Z/DS1000Z User’s Guide 8-15 SPI Decoding (Option) SPI bus is based on the master-slave configuration a
RIGOL Chapter 8 Protocol Decoding 8-16 MSO1000Z/DS1000Z User’s Guide 5. Mode Timeout: you can perform frame synchronization according to the tim
Chapter 8 Protocol Decoding RIGOL MSO1000Z/DS1000Z User’s Guide 8-17 time and data are displayed in the event table; if “Details” is selected, t
Chapter 9 Reference Waveform RIGOL MSO1000Z/DS1000Z User’s Guide 9-1 Chapter 9 Reference Waveform In the actual test process, you can compare th
RIGOL Chapter 9 Reference Waveform 9-2 MSO1000Z/DS1000Z User’s Guide To Enable REF Function Press REF in the vertical control area (VERTICAL) at th
Chapter 9 Reference Waveform RIGOL MSO1000Z/DS1000Z User’s Guide 9-3 To Set the Color MSO1000Z/DS1000Z series oscilloscope provides five colors
Chapter 10 Pass/Fail Test RIGOL MSO1000Z/DS1000Z User’s Guide 10-1 Chapter 10 Pass/Fail Test During the product design and manufacture process, y
RIGOL XVI MSO1000Z/DS1000Z User’s Guide Content Conventions in this Manual: MSO1000Z/DS1000Z series includes the following models. This manual tak
RIGOL Chapter 10 Pass/Fail Test 10-2 MSO1000Z/DS1000Z User’s Guide To Enable Pass/Fail Test Press Utility Pass/Fail Enable to select “ON”. The
Chapter 10 Pass/Fail Test RIGOL MSO1000Z/DS1000Z User’s Guide 10-3 Test and Output You can set the output form of the test results by the follo
RIGOL Chapter 10 Pass/Fail Test 10-4 MSO1000Z/DS1000Z User’s Guide To Load the Test Mask Users can also load the test mask files (*.pf) stored in t
Chapter 11 Waveform Record RIGOL MSO1000Z/DS1000Z User’s Guide 11-1 Chapter 11 Waveform Record Waveform record can record the waveforms of the an
RIGOL Chapter 11 Waveform Record 11-2 MSO1000Z/DS1000Z User’s Guide Common Settings Press Utility Record Record to turn on or off the wavefor
Chapter 11 Waveform Record RIGOL MSO1000Z/DS1000Z User’s Guide 11-3 Playback Option Waveform playback can play back the waveforms currently rec
RIGOL Chapter 11 Waveform Record 11-4 MSO1000Z/DS1000Z User’s Guide Record Option Before recording the waveform, you can press Record Opt to set
Chapter 12 Display Control RIGOL MSO1000Z/DS1000Z User’s Guide 12-1 Chapter 12 Display Control You can set the type, persistence time and brightn
RIGOL Chapter 12 Display Control 12-2 MSO1000Z/DS1000Z User’s Guide To Select the Display Type Press Display Type to set the waveform display mod
Chapter 12 Display Control RIGOL MSO1000Z/DS1000Z User’s Guide 12-3 3. Infinite In this mode, the oscilloscope displays the waveform newly acqu
Contents RIGOL MSO1000Z/DS1000Z User’s Guide XVII Contents Guaranty and Declaration ...
Chapter 13 Signal Source RIGOL MSO1000Z/DS1000Z User’s Guide 13-1 Chapter 13 Signal Source MSO1000Z/DS1000Z combines signal generator and oscillo
RIGOL Chapter 13 Signal Source 13-2 MSO1000Z/DS1000Z User’s Guide To Output Basic Waveform MSO1000Z/DS1000Z built-in signal source can output a var
Chapter 13 Signal Source RIGOL MSO1000Z/DS1000Z User’s Guide 13-3 6. Align phase Pressing AlignPhase will re-configure the two channels to outp
RIGOL Chapter 13 Signal Source 13-4 MSO1000Z/DS1000Z User’s Guide TtSymmetry=t/T*100% Figure 13-1 Symmetry Definition Press Symmetry to set the sym
Chapter 13 Signal Source RIGOL MSO1000Z/DS1000Z User’s Guide 13-5 To Output Pulse Press Src1Conf to open the waveform setting menu. Press Wave
RIGOL Chapter 13 Signal Source 13-6 MSO1000Z/DS1000Z User’s Guide To Output Noise Press Src1Conf to open the waveform setting menu. Press Wave and
Chapter 13 Signal Source RIGOL MSO1000Z/DS1000Z User’s Guide 13-7 Figure 13-3 Built-in Waveform-Sinc Figure 13-4 Built-in Waveform-ExpRise
RIGOL Chapter 13 Signal Source 13-8 MSO1000Z/DS1000Z User’s Guide Figure 13-6 Built-in Waveform-ECG Figure 13-7 Built-in Waveform-Gauss Figure
Chapter 13 Signal Source RIGOL MSO1000Z/DS1000Z User’s Guide 13-9 Figure 13-9 Built-in Waveform-Haversine 3. Set the frequency Press Frequenc
RIGOL Contents XVIII MSO1000Z/DS1000Z User’s Guide To Use the Built-in Help System ... 1-2
RIGOL Chapter 13 Signal Source 13-10 MSO1000Z/DS1000Z User’s Guide 8. Modulation Press Src1Mod to enter the modulation setting interface. For detai
Chapter 13 Signal Source RIGOL MSO1000Z/DS1000Z User’s Guide 13-11 6. Align Phase The align phase operation is for the two channels. Pressing A
RIGOL Chapter 13 Signal Source 13-12 MSO1000Z/DS1000Z User’s Guide Channel Signal Select the signals of analog channel (CH1-CH4) turned on curren
Chapter 13 Signal Source RIGOL MSO1000Z/DS1000Z User’s Guide 13-13 OFF: the waveform editor will keep a constant voltage level between two
RIGOL Chapter 13 Signal Source 13-14 MSO1000Z/DS1000Z User’s Guide 8. Delete Press Delete to delete the current point from the waveform and connect
Chapter 13 Signal Source RIGOL MSO1000Z/DS1000Z User’s Guide 13-15 5. Time Press Time to set the duration of the current point. This setting is
RIGOL Chapter 13 Signal Source 13-16 MSO1000Z/DS1000Z User’s Guide AM AM (Amplitude Modulation), namely the amplitude of the carrier waveform chang
Chapter 13 Signal Source RIGOL MSO1000Z/DS1000Z User’s Guide 13-17 5. Set the Modulation Depth The modulation depth refers to the strength of t
RIGOL Chapter 13 Signal Source 13-18 MSO1000Z/DS1000Z User’s Guide 4. Set the Modulation Frequency Press Frequency to set the frequency of the modu
Chapter 14 Store and Recall RIGOL MSO1000Z/DS1000Z User’s Guide 14-1 Chapter 14 Store and Recall Users can save the current settings, waveforms,
Contents RIGOL MSO1000Z/DS1000Z User’s Guide XIX Setup/Hold Trigger (Option) ... 5-27 N
RIGOL Chapter 14 Store and Recall 14-2 MSO1000Z/DS1000Z User’s Guide Storage System Press Storage to enter the store and recall setting interface.
Chapter 14 Store and Recall RIGOL MSO1000Z/DS1000Z User’s Guide 14-3 4. Setups Save the settings of the oscilloscope to internal or external me
RIGOL Chapter 14 Store and Recall 14-4 MSO1000Z/DS1000Z User’s Guide Internal Storage and Recall “Setups” and “Param” (internal recall is not suppo
Chapter 14 Store and Recall RIGOL MSO1000Z/DS1000Z User’s Guide 14-5 External Storage and Recall Before using external storage and recall, make
RIGOL Chapter 14 Store and Recall 14-6 MSO1000Z/DS1000Z User’s Guide Disk Management Press Storage DiskManage to turn on the disk management inte
Chapter 14 Store and Recall RIGOL MSO1000Z/DS1000Z User’s Guide 14-7 To Create a New File or Folder This operation is only valid in external st
RIGOL Chapter 14 Store and Recall 14-8 MSO1000Z/DS1000Z User’s Guide English Input Method For example, create a file or folder with the name “Filen
Chapter 14 Store and Recall RIGOL MSO1000Z/DS1000Z User’s Guide 14-9 Chinese Input Method For example, create a file or folder with the name “文
RIGOL Chapter 14 Store and Recall 14-10 MSO1000Z/DS1000Z User’s Guide To Delete a File or Folder Folder operation is valid only in external storage
Chapter 14 Store and Recall RIGOL MSO1000Z/DS1000Z User’s Guide 14-11 Factory Press Storage Default to return the oscilloscope to its factor
RIGOL Contents XX MSO1000Z/DS1000Z User’s Guide To Set the Waveform Display Size ... 7-4 Re
RIGOL Chapter 14 Store and Recall 14-12 MSO1000Z/DS1000Z User’s Guide Sin(x)/x ON Memory Depth Auto Anti-Aliasing OFF Trigger Setting (TRIGGER) Tri
Chapter 14 Store and Recall RIGOL MSO1000Z/DS1000Z User’s Guide 14-13 CursorA Source CH1 CursorB Source CH1 CursorA -4.000 μs CursorB 4.000 μs X
RIGOL Chapter 14 Store and Recall 14-14 MSO1000Z/DS1000Z User’s Guide A×B Operation OFF Source A CH1 Source B CH1 Offset 0.00 U Scale 2.00 U A/B Ope
Chapter 14 Store and Recall RIGOL MSO1000Z/DS1000Z User’s Guide 14-15 Threshold A 0.00 V Threshold B 0.00 V !A Operation OFF Source A D0 Offset
RIGOL Chapter 14 Store and Recall 14-16 MSO1000Z/DS1000Z User’s Guide LA[2] Current Channel D0 D7-D0 OFF D15-D8 OFF Wave Size S ReOrder D0-D15 Delay
Chapter 14 Store and Recall RIGOL MSO1000Z/DS1000Z User’s Guide 14-17 MOSI CH2 Mode Timeout Timeout 1.00 us Edge Rising Edge Polarity Width 8 O
Chapter 15 Accessibility Setting RIGOL MSO1000Z/DS1000Z User’s Guide 15-1 Chapter 15 Accessibility Setting The contents of this chapter: Remot
RIGOL Chapter 15 Accessibility Setting 15-2 MSO1000Z/DS1000Z User’s Guide Remote Interface Configuration MSO1000Z/DS1000Z provides three remote c
Chapter 15 Accessibility Setting RIGOL MSO1000Z/DS1000Z User’s Guide 15-3 LAN Configuration Press Utility IO Setting LAN Conf. to turn on t
Contents RIGOL MSO1000Z/DS1000Z User’s Guide XXI To Output Pulse ... 1
RIGOL Chapter 15 Accessibility Setting 15-4 MSO1000Z/DS1000Z User’s Guide DHCP Press Configure and use to select “DHCP”. Then press down to s
Chapter 15 Accessibility Setting RIGOL MSO1000Z/DS1000Z User’s Guide 15-5 DHCP and Auto IP will be “Off” and the oscilloscope will load the pres
RIGOL Chapter 15 Accessibility Setting 15-6 MSO1000Z/DS1000Z User’s Guide MAC Address For each oscilloscope, the MAC address is unique. When attr
Chapter 15 Accessibility Setting RIGOL MSO1000Z/DS1000Z User’s Guide 15-7 System-related Sound When the sound is enabled, you can hear the sou
RIGOL Chapter 15 Accessibility Setting 15-8 MSO1000Z/DS1000Z User’s Guide Self-calibration The self-calibration program can quickly make the osci
Chapter 15 Accessibility Setting RIGOL MSO1000Z/DS1000Z User’s Guide 15-9 MSO1000Z/DS1000Z digital oscilloscope supports the PictBridge printer
RIGOL Chapter 15 Accessibility Setting 15-10 MSO1000Z/DS1000Z User’s Guide select the desired file type. You can also press this key continuously
Chapter 15 Accessibility Setting RIGOL MSO1000Z/DS1000Z User’s Guide 15-11 Option Management This oscilloscope provides multiple options to ful
RIGOL Chapter 15 Accessibility Setting 15-12 MSO1000Z/DS1000Z User’s Guide Auto Options As mentioned before, pressing AUTO at the front panel can
Chapter 16 Remote Control RIGOL MSO1000Z/DS1000Z User’s Guide 16-1 Chapter 16 Remote Control MSO1000Z/DS1000Z oscilloscope can be controlled remo
RIGOL Contents XXII MSO1000Z/DS1000Z User’s Guide Chapter 17 Troubleshooting ... 17-1 Chapter
RIGOL Chapter 16 Remote Control 16-2 MSO1000Z/DS1000Z User’s Guide Remote Control via USB 1. Connect the device Connect the USB Device interface
Chapter 16Remote Control RIGOL MSO1000Z/DS1000Z User’s Guide 16-3 3 4 5 6
RIGOL Chapter 16 Remote Control 16-4 MSO1000Z/DS1000Z User’s Guide 3. Search for device resource Start up Ultra Sigma and the software will a
Chapter 16Remote Control RIGOL MSO1000Z/DS1000Z User’s Guide 16-5 4. View the device resource The resources found will appear under the “RIGOL
RIGOL Chapter 16 Remote Control 16-6 MSO1000Z/DS1000Z User’s Guide Remote Control via LAN 1. Connect the device Connect the oscilloscope to your
Chapter 16Remote Control RIGOL MSO1000Z/DS1000Z User’s Guide 16-7 5. Communication test Right click the resource name “MSO1104Z (TCPIP::172.1
RIGOL Chapter 16 Remote Control 16-8 MSO1000Z/DS1000Z User’s Guide Remote Control via GPIB 1. Connect the device Use the USB to GPIB interface c
Chapter 16Remote Control RIGOL MSO1000Z/DS1000Z User’s Guide 16-9 select the GPIB address set in the oscilloscope from the comboBox of “0::INSTR
Chapter 17 Troubleshooting RIGOL MSO1000Z/DS1000Z User’s Guide 17-1 Chapter 17 Troubleshooting The commonly encountered failures and their soluti
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-1 Chapter 1 Quick Start This chapter introduces the precautions when using the osc
RIGOL Chapter 17 Troubleshooting 17-2 MSO1000Z/DS1000Z User’s Guide 6. The display of waveform is ladder-like: (1) The horizontal time base migh
Chapter 18 Specifications RIGOL MSO1000Z/DS1000Z User’s Guide 18-1 Chapter 18 Specifications All the specifications are guaranteed except the par
RIGOL Chapter 18 Specifications 18-2 MSO1000Z/DS1000Z User’s Guide Horizontal Timebase Scale 5 ns/div to 50 s/div Max Record Length 24 Mpts (option
Chapter 18 Specifications RIGOL MSO1000Z/DS1000Z User’s Guide 18-3 Vertical (Digital Channel) Threshold Adjustable threshold of 8 channels per g
RIGOL Chapter 18 Specifications 18-4 MSO1000Z/DS1000Z User’s Guide Pulse Width Range 8 ns to 10 s Window Trigger (Option) Window Type Rising, Falli
Chapter 18 Specifications RIGOL MSO1000Z/DS1000Z User’s Guide 18-5 Data Bits 5 bit, 6 bit, 7 bit, 8 bit I2C Trigger (Option) Trigger Condition S
RIGOL Chapter 18 Specifications 18-6 MSO1000Z/DS1000Z User’s Guide Math Operation Waveform Operation A+B, A-B, A×B, A/B, FFT, A&&B, A||B, A
Chapter 18 Specifications RIGOL MSO1000Z/DS1000Z User’s Guide 18-7 (Non-harmonic) Total Harmonic Distortion 1% S/N Ratio 40 dB Square/Pulse Freq
RIGOL Chapter 18 Specifications 18-8 MSO1000Z/DS1000Z User’s Guide General Specifications Probe Compensation Output Output Voltage[1] About 3 V, pe
Chapter 19 Appendix RIGOL MSO1000Z/DS1000Z User’s Guide 19-1 Chapter 19 Appendix Appendix A: Accessories and Options Description Order Number M
RIGOL Chapter 1 Quick Start 1-2 MSO1000Z/DS1000Z User’s Guide General Inspection 1. Inspect the shipping container for damage. Keep the damaged
RIGOL Chapter 19 Appendix 19-2 MSO1000Z/DS1000Z User’s Guide Appendix B: Warranty RIGOL warrants that its products mainframe and accessories will
Index RIGOL MSO1000Z/DS1000Z User’s Guide 1 Index - Duty ... 6-22 - Width ...
RIGOL Index 2 MSO1000Z/DS1000Z User’s Guide Ramp ... 13-3 -Rate ... 6-25 Rect
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-3 Appearance and Dimensions Figure 1-1 Front View Unit: mm
RIGOL Chapter 1 Quick Start 1-4 MSO1000Z/DS1000Z User’s Guide To Prepare the Oscilloscope for Use To Adjust the Supporting Legs Adjust the suppo
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-5 Power-on Inspection When the oscilloscope is energized, pressing the power key a
RIGOL MSO1000Z/DS1000Z User’s Guide I Guaranty and Declaration Copyright © 2014 RIGOL Technologies, Inc. All Rights Reserved. Trademark Informa
RIGOL Chapter 1 Quick Start 1-6 MSO1000Z/DS1000Z User’s Guide Connect the logic probe: 1. Connect the single-wire terminal of the logic probe to
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-7 Function Inspection 1. Press Storage Default to restore the oscilloscope to it
RIGOL Chapter 1 Quick Start 1-8 MSO1000Z/DS1000Z User’s Guide Probe Compensation When the probes are used for the first time, you should compensa
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-9 Front Panel Overview Figure 1-10 Front Panel Overview Table 1-1 Front Pane
RIGOL Chapter 1 Quick Start 1-10 MSO1000Z/DS1000Z User’s Guide Rear Panel Overview Figure 1-11 Rear Panel Overview 1. Handle Pull up the ha
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-11 Pass/Fail: The instrument can output a positive pulse via this connector when
RIGOL Chapter 1 Quick Start 1-12 MSO1000Z/DS1000Z User’s Guide Front Panel Function Overview VERTICAL CH1, CH2, CH3, CH4: analog channel settin
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-13 Logic Analyzer Press this key to open the logic analyzer control menu. You can
RIGOL Chapter 1 Quick Start 1-14 MSO1000Z/DS1000Z User’s Guide HORIZONTAL HORIZONTAL POSITION: modify the horizontal position. The trigger po
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-15 TRIGGER MODE: press this key to switch the trigger mode to Auto, Normal or Sing
RIGOL II MSO1000Z/DS1000Z User’s Guide Safety Requirement General Safety Summary Please review the following safety precautions carefully before
RIGOL Chapter 1 Quick Start 1-16 MSO1000Z/DS1000Z User’s Guide RUN/STOP Press this key to “RUN” or “STOP” waveform sampling. In the “RUN” state,
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-17 Function Menus Measure: press this key to open the measurement setting menu. Y
RIGOL Chapter 1 Quick Start 1-18 MSO1000Z/DS1000Z User’s Guide Print Press this key to print the screen or save the screen to a USB storage devi
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-19 User Interface MSO1000Z/DS1000Z provides 7.0 inch, WVGA (800*480) 160,000 color
RIGOL Chapter 1 Quick Start 1-20 MSO1000Z/DS1000Z User’s Guide 3. Status Available states include RUN, STOP, T’D (triggered), WAIT and AUTO. 4.
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-21 level value will change with the up and down of . Note: In slope trigger, runt t
RIGOL Chapter 1 Quick Start 1-22 MSO1000Z/DS1000Z User’s Guide 19. Source1 Waveform Display the type of waveform currently set for Source1.
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-23 Parameter Setting Method MSO1000Z/DS1000Z supports the following two parameter s
RIGOL Chapter 1 Quick Start 1-24 MSO1000Z/DS1000Z User’s Guide To Use the Security Lock If needed, you can use the security lock (please buy it y
Chapter 1 Quick Start RIGOL MSO1000Z/DS1000Z User’s Guide 1-25 To Use the Built-in Help System The help system of this oscilloscope provides in
RIGOL MSO1000Z/DS1000Z User’s Guide III Do Not Operate with Suspected Failures. If you suspect damage occurs to the instrument, have it inspect
Chapter 2 To Set the Vertical System RIGOL MSO1000Z/DS1000Z User’s Guide 2-1 Chapter 2 To Set the Vertical System The contents of this chapter
RIGOL Chapter 2 To Set the Vertical System 2-2 MSO1000Z/DS1000Z User’s Guide To Enable the Analog Channel MSO1000Z/DS1000Z provides 4 analog input
Chapter 2 To Set the Vertical System RIGOL MSO1000Z/DS1000Z User’s Guide 2-3 Bandwidth Limit MSO1000Z/DS1000Z supports the bandwidth limit func
RIGOL Chapter 2 To Set the Vertical System 2-4 MSO1000Z/DS1000Z User’s Guide Waveform Invert Press CH1 Invert to enable or disable waveform inver
Chapter 2 To Set the Vertical System RIGOL MSO1000Z/DS1000Z User’s Guide 2-5 Note: You can also press VERTICAL SCALE to quickly switch betwee
RIGOL Chapter 2 To Set the Vertical System 2-6 MSO1000Z/DS1000Z User’s Guide For example, set the label to “ ”. Press Keyboard to select the “Keyboa
Chapter 2 To Set the Vertical System RIGOL MSO1000Z/DS1000Z User’s Guide 2-7 Delay Calibration of the Analog Channel When using an oscilloscope
Chapter 3 To Set the Horizontal System RIGOL MSO1000Z/DS1000Z User’s Guide 3-1 Chapter 3 To Set the Horizontal System The contents of this chapt
RIGOL IV MSO1000Z/DS1000Z User’s Guide Safety Terms and Symbols Terms Used in this Manual. These terms may appear in this manual: WARNING Warn
RIGOL Chapter 3 To Set the Horizontal System 3-2 MSO1000Z/DS1000Z User’s Guide Delayed Sweep Delayed sweep can be used to enlarge a length of wav
Chapter 3 To Set the Horizontal System RIGOL MSO1000Z/DS1000Z User’s Guide 3-3 Tip You can also press down HORIZONTAL SCALE (delayed sweep sh
RIGOL Chapter 3 To Set the Horizontal System 3-4 MSO1000Z/DS1000Z User’s Guide According to sinθ=A/B or C/D (wherein, θ is the phase deviation ang
Chapter 3 To Set the Horizontal System RIGOL MSO1000Z/DS1000Z User’s Guide 3-5 Note: The maximum sample rate of XY mode is 500 MSa/s. General
Chapter 4 To Set the Sample System RIGOL MSO1000Z/DS1000Z User’s Guide 4-1 Chapter 4 To Set the Sample System The contents of this chapter:
RIGOL Chapter 4 To Set the Sample System 4-2 MSO1000Z/DS1000Z User’s Guide Acquisition Mode The acquisition mode is used to control how to generate
Chapter 4 To Set the Sample System RIGOL MSO1000Z/DS1000Z User’s Guide 4-3 Figure 4-1 The Waveform before Average Figure 4-2 The Waveform aft
RIGOL Chapter 4 To Set the Sample System 4-4 MSO1000Z/DS1000Z User’s Guide Sin(x)/x Press Sin(x)/x to enable or disable the dynamic sine interpolat
Chapter 4 To Set the Sample System RIGOL MSO1000Z/DS1000Z User’s Guide 4-5 3. Waveform Leakage: when the sample rate is too low, the waveform r
RIGOL MSO1000Z/DS1000Z User’s Guide V Allgemeine Sicherheits Informationen Überprüfen Sie diefolgenden Sicherheitshinweise sorgfältigumPersone
RIGOL Chapter 4 To Set the Sample System 4-6 MSO1000Z/DS1000Z User’s Guide Memory Depth Memory depth refers to the number of waveform points that t
Chapter 4 To Set the Sample System RIGOL MSO1000Z/DS1000Z User’s Guide 4-7 (option). For digital channels: ― When 8 channels are enabled, t
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-1 Chapter 5 To Trigger the Oscilloscope As for trigger, you set cert
RIGOL Chapter 5 To Trigger the Oscilloscope 5-2 MSO1000Z/DS1000Z User’s Guide Trigger Source Press MENU Source in the trigger control area (TRIGG
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-3 Trigger Mode Trigger mode affects the way in which the oscillosco
RIGOL Chapter 5 To Trigger the Oscilloscope 5-4 MSO1000Z/DS1000Z User’s Guide bar and stable waveform is displayed. Otherwise, “WAIT” is displayed a
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-5 Trigger Holdoff Trigger holdoff can be used to stably trigger com
RIGOL Chapter 5 To Trigger the Oscilloscope 5-6 MSO1000Z/DS1000Z User’s Guide Trigger Type MSO1000Z/DS1000Z provides various trigger functions, inc
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-7 Edge Trigger Trigger on the trigger threshold of the specified ed
RIGOL VI MSO1000Z/DS1000Z User’s Guide Betreiben Sie das Gerät nicht im Fehlerfall. Wenn Sie am Gerät einen Defekt vermuten, sorgen Sie dafür, bevo
RIGOL Chapter 5 To Trigger the Oscilloscope 5-8 MSO1000Z/DS1000Z User’s Guide Pulse Trigger Trigger on the positive or negative pulse with a specif
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-9 of pulse width. : trigger when the negative pulse width of the i
RIGOL Chapter 5 To Trigger the Oscilloscope 5-10 MSO1000Z/DS1000Z User’s Guide Slope Trigger In slope trigger, the oscilloscope triggers on the pos
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-11 : trigger when the negative slope time of the input signal is
RIGOL Chapter 5 To Trigger the Oscilloscope 5-12 MSO1000Z/DS1000Z User’s Guide (a) (b) Figure 5-5 Trigger Level
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-13 Video Trigger The waveform of video signal includes image signal
RIGOL Chapter 5 To Trigger the Oscilloscope 5-14 MSO1000Z/DS1000Z User’s Guide line-by-line sweep. Trigger Mode: Press Sweep to open the trigger mo
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-15 Pattern Trigger Identify a trigger condition by looking for a sp
RIGOL Chapter 5 To Trigger the Oscilloscope 5-16 MSO1000Z/DS1000Z User’s Guide Note: When digital channels D7-D0 are enabled, CH4 is automatical
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-17 Duration Trigger In duration trigger, the instrument identifies
RIGOL MSO1000Z/DS1000Z User’s Guide VII Sicherheits Begriffe und Symbole Begriffe in diesem Guide. Diese Begriffe können in diesem Handbuch au
RIGOL Chapter 5 To Trigger the Oscilloscope 5-18 MSO1000Z/DS1000Z User’s Guide : set the pattern of the channel selected to “Don’t Care”, namely
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-19 TimeOut Trigger (Option) In timeout trigger, the instrument trig
RIGOL Chapter 5 To Trigger the Oscilloscope 5-20 MSO1000Z/DS1000Z User’s Guide Timeout Time: Timeout time represents the minimum time that the clock
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-21 Runt Trigger (Option) This trigger mode is used to trigger pulse
RIGOL Chapter 5 To Trigger the Oscilloscope 5-22 MSO1000Z/DS1000Z User’s Guide pulse width of runt trigger and the range is from 16.0 ns to 10.0 s;
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-23 Window Trigger (Option) Window trigger provides a high trigger l
RIGOL Chapter 5 To Trigger the Oscilloscope 5-24 MSO1000Z/DS1000Z User’s Guide Trigger Mode: Press Sweep to open the trigger mode list and select
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-25 Delay Trigger (Option) In delay trigger, you need to set signal
RIGOL Chapter 5 To Trigger the Oscilloscope 5-26 MSO1000Z/DS1000Z User’s Guide >: trigger when the time difference (△T) between the specified
Chapter 5 To Trigger the Oscilloscope RIGOL MSO1000Z/DS1000Z User’s Guide 5-27 Setup/Hold Trigger (Option) Setup time (△T1) indicates the time