DSA1000 Series Economic Spectrum Analyzer
Features and Benets
Key Specications
9 kHz to 2 GHz or 3 GHz Frequency Range
-138 dBm Displayed Average Noise Level
-80 dBc/Hz @10 kHz offset Phase Noise
Total Amplitude Uncertainty <1.5 dB
100 Hz Minimum Resolution Bandwidth (RBW)
3 GHz Tracking Generator (DSA1030 optional)
Advanced measurement functions (DSA1030 optional) and automatic
settings provide ultimate exibility
8.5 inch widescreen display with clear, vivid, and easy to use graphical interface
Various interface options such as LAN\USB Host, USB Device, VGA or GPIB (optional)
Compact design with a weight of only 13.7 lbs
Frequency
DSA1020
DSA1030
Frequency
Frequency Range
Frequency Resolution
9 kHz to 2 GHz
9 kHz to 3 GHz
1 Hz
20
to 30
10 MHz
<3 ppm/year
<3 ppm
Internal Frequency Reference
Reference Frequency
Aging Rate
Temperature Drift
10 kHz
Note: typical fc = 500 MHz, RBW≤1 kHz, sample detector, and trace average≥50.
SSB phase noise
Carrier Offset
Bandwidths
Resolution Bandwidth (-3 dB)
RBW Uncertainty
Resolution Filter Shape Factor
(60 dB: 3 dB)
Video Bandwidth (-3 dB)
<-80 dBc/Hz
100 Hz to 1 MHz, in 1-3-10 sequence
< 5%, nominal
< 5, nominal
1 Hz to 3 MHz, in 1-3-10 sequence
Amplitude
50 V
30 dBm (1W)
40 dBm (10W)
Note: when input level >33 dBm, the protection switch will be on.
Measurement Range
Range
Maximum rated input level
DC Voltage
CW RF Power
Max. Damage Level
DANL to +30 dBm
RF attenuation ≥ 20 dB
DANL (Preamplier Off)
100 kHz to 10 MHz
10 MHz to 2.5 GHz
2.5 GHz to 3 GHz
100 kHz to 1 MHz
1 MHz to 10 MHz
10 MHz to 2.5 GHz
2.5 GHz to 3 GHz
<-75 dBm-3 × (f/1 MHz) dB, typ. -115 dBm
<-117 dBm+3 × (f/1 GHz) dB, typ. -120 dBm
<-105 dBm
<-93 dBm
<-93 dBm-3 × (f/1 MHz) dB, typ. -133 dBm
<-135 dBm+3 × (f/1 GHz) dB, typ. -138 dBm
<-123 dBm
DANL (Preamplier On)
Displayed Average Noise Level (DSA1030)
0 dB RF Attenuation, RBW=100Hz, VBW=10Hz, Sample Detector, Trace Average ≥ 50
95% condence level, S/N>20 dB,
RBW=VBW=1kHz, preamplier off,
10 dB RF attenuation,
-50 dBm<Reference level<0,
10 MHz<fc<2GHz (DSA1020) ,
10 MHz<fc<3GHz (DSA1030),
20 ºC to 30 ºC
<1.5 dB, nominal
Level Measurement Uncertainty
Overall Amplitude
Measurement Uncertainty
REKIRSCH Elektronik - messen Sie uns an unserem Service