RIGOL
12
DSA1000 Series Economic Spectrum Analyzer
Features and Benets
Key Specications
9 kHz to 2 GHz or 3 GHz Frequency Range
-138 dBm Displayed Average Noise Level
-80 dBc/Hz @10 kHz offset Phase Noise
Total Amplitude Uncertainty <1.5 dB
100 Hz Minimum Resolution Bandwidth (RBW)
3 GHz Tracking Generator (DSA1030 optional)
Advanced measurement functions (DSA1030 optional) and automatic
settings provide ultimate exibility
8.5 inch widescreen display with clear, vivid, and easy to use graphical interface
Various interface options such as LAN\USB Host, USB Device, VGA or GPIB (optional)
Compact design with a weight of only 13.7 lbs
Frequency
DSA1020
DSA1030
Frequency
Frequency Range
Frequency Resolution
9 kHz to 2 GHz
9 kHz to 3 GHz
1 Hz
20
℃
to 30
℃
10 MHz
<3 ppm/year
<3 ppm
Internal Frequency Reference
Reference Frequency
Aging Rate
Temperature Drift
10 kHz
Note: typical fc = 500 MHz, RBW≤1 kHz, sample detector, and trace average≥50.
SSB phase noise
Carrier Offset
Bandwidths
Resolution Bandwidth (-3 dB)
RBW Uncertainty
Resolution Filter Shape Factor
(60 dB: 3 dB)
Video Bandwidth (-3 dB)
<-80 dBc/Hz
100 Hz to 1 MHz, in 1-3-10 sequence
< 5%, nominal
< 5, nominal
1 Hz to 3 MHz, in 1-3-10 sequence
Amplitude
50 V
30 dBm (1W)
40 dBm (10W)
Note: when input level >33 dBm, the protection switch will be on.
Measurement Range
Range
Maximum rated input level
DC Voltage
CW RF Power
Max. Damage Level
DANL to +30 dBm
RF attenuation ≥ 20 dB
DANL (Preamplier Off)
100 kHz to 10 MHz
10 MHz to 2.5 GHz
2.5 GHz to 3 GHz
100 kHz to 1 MHz
1 MHz to 10 MHz
10 MHz to 2.5 GHz
2.5 GHz to 3 GHz
<-75 dBm-3 × (f/1 MHz) dB, typ. -115 dBm
<-117 dBm+3 × (f/1 GHz) dB, typ. -120 dBm
<-105 dBm
<-93 dBm
<-93 dBm-3 × (f/1 MHz) dB, typ. -133 dBm
<-135 dBm+3 × (f/1 GHz) dB, typ. -138 dBm
<-123 dBm
DANL (Preamplier On)
Displayed Average Noise Level (DSA1030)
0 dB RF Attenuation, RBW=100Hz, VBW=10Hz, Sample Detector, Trace Average ≥ 50
95% condence level, S/N>20 dB,
RBW=VBW=1kHz, preamplier off,
10 dB RF attenuation,
-50 dBm<Reference level<0,
10 MHz<fc<2GHz (DSA1020) ,
10 MHz<fc<3GHz (DSA1030),
20 ºC to 30 ºC
<1.5 dB, nominal
Level Measurement Uncertainty
Overall Amplitude
Measurement Uncertainty
REKIRSCH Elektronik - messen Sie uns an unserem Service