2. Set up the channel bandwidth limit
To use CH1 as an example, input a signal that contains high frequency component.
Press CH1BW LimitOFF, to set up bandwidth limit to “OFF” status. The
oscilloscope is set to full bandwidth and the high frequency component in the signal
will pass.
The waveform is displayed as Figure 2-6:
Press CH1BW LimitON, to set up bandwidth limit toON” status. It will reject
the frequency component higher than 20MHz.
The waveform is displayed as Figure 2-7:
Turn off the BW
limit
Figure 2-6
Figure 2-7
20M BW limit
Mark of