Chapter 2 Command System RIGOL
DS1000Z Programming Guide 2-81
:TIMebase[:MAIN]:SCALe
Syntax :TIMebase[:MAIN]:SCALe <scale_value>
Set or query the main timebase scale. The default unit is s/div.
Parameter
<scale_value> Real Normal: 5ns to 50s in 1-2-5 step
Roll: 200ms to 50s in 1-2-5 step
1μs
Explanation When the horizontal timebase is YT and the timebase scale is 20ms or larger (namely
“Slow Sweep” mode), this command is invalid when the oscilloscope in Stoping.
The query returns the main timebase scale in scientific notation.
Example :TIMebase:MAIN:SCALe 0.0002 /*Set the main timebase scale to 200μs*/
:TIMebase:MAIN:SCALe? /*The query returns 2.0000000e-04*/
Related
Command
:TIMebase:MODE
:TIMebase:MODE
Syntax :TIMebase:MODE <mode>
Set or query the mode of the horizontal timebase.
Parameter
The query returns MAIN, XY or ROLL.
Related
Command
:TIMebase:DELay:OFFSet
:TIMebase:DELay:SCALe
:TIMebase[:MAIN]:OFFSet
:TIMebase[:MAIN]:SCALe