RIGOL Command Systems
Programming Guide for DS1000B Series
2-6
1. :RUN
Command Format:
:RUN
Function:
Execute this command, the oscilloscope will start waveform sampling working.
To stop working, execute :STOP command again.
2. :STOP
Command Format:
:STOP
Function:
Execute this command, the oscilloscope will stop waveform sampling working.
To restart working, execute :RUN command again.
3. :AUTO
Command Format:
:AUTO
Function:
The command makes the oscilloscope tests all input waveforms and set the
waveforms automatically to get the optimum conditions to display.
4. :SYSTem:ERRor
Command Format:
:SYSTem:ERRor
:SYSTem:ERRor?
Function:
The command clears the queue of error information.
Returned Format: