Rigol M300 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Rigol M300 herunter. RIGOL M300 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Programming Guide

RIGOL Programming Guide DM3000 Series Digital Multimeter Oct. 2012 RIGOL Technologies, Inc.

Seite 2

RIGOL Chapter 1 Programming Overview Programming Guide for DM3000 1-

Seite 3 - Guaranty and Declaration

Chapter 1 Programming Overview RIGOL Programming Guide for DM3000 1-5 Command Set Introduction T

Seite 5 - Contents

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-1 Chapter 2 Command System In RIGOL DM3000 series digital multimeter command set,

Seite 6

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-2 Common Commands The commands are used to query the basic information of the instrum

Seite 7

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-3 1. *CLS Syntax *CLS Function Cl

Seite 8 - Programming Introduction

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-4 :FUNCtion Commands The commands are used to enable the common measurement functions

Seite 9 - Symbol Description

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-5 1. :FUNCtion? Syntax :FUNCtion?

Seite 10 - Parameter Type

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-6 Syntax :FUNCtion:FRESistance Function Enable the 4-wire resistance measurement funct

Seite 11 - Command Set Introduction

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-7 :MEASure Commands The commands

Seite 13 - Chapter 2 Command System

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-8 1. :MEASure? Syntax :MEASure? Function Query whether the current measurement is fi

Seite 14 - Common Commands

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-9 Function Query the current rang

Seite 15 - Programming Guide for DM3000

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-10 Function The query returns the ratio of two DC voltages in scientific notation, fo

Seite 16 - :FUNCtion Commands

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-11 12. :MEASure:VOLTage:AC:RANGe?

Seite 17

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-12 17. :MEASure:VOLTage:AC:FREQuency:HIDE Syntax :MEASure:VOLTage:AC:FREQuency:HIDE Fu

Seite 18

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-13 21. :MEASure:CURRent:DC:RANGe?

Seite 19 - :MEASure Commands

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-14 :MEASure:CURRent:AC MAX 25. :MEASure:CURRent:AC:RANGe? Syntax :MEASure:CURRent:AC

Seite 20

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-15 secondary display is enabled in

Seite 21

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-16 Function Query the current range of 2-wire resistance measurement. The query retur

Seite 22

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-17 Explanation Refer to the “Expla

Seite 23

RIGOL Programming Guide for DM3000 I Guaranty and Declaration Copyright © 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information

Seite 24

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-18 43. :MEASure:PERiod? Syntax :MEASure:PERiod? Function The query returns the period

Seite 25

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-19 Syntax :MEASure:CONTinuity {<

Seite 26

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-20 Parameter Range DM306x DM305x 0 2 nF 4 nF 1 20 nF 40 nF 2 200 nF 400 nF 3

Seite 27

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-21 :RESOlution Commands The com

Seite 28

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-22 1. :RESOlution:VOLTage:DC Syntax :RESOlution:VOLTage:DC? :RESOlution:VOLTage:DC {

Seite 29

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-23 :RESOlution:VOLTage:AC {0|1|2|M

Seite 30

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-24 :RESOlution:CURRent:DC 1 5. :RESOlution:CURRent:AC Syntax :RESOlution:CURRent:AC?

Seite 31 - <value>

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-25 Example Set the reading resolu

Seite 32

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-26 :SYSTem Commands The commands are used to set the system parameters of the multi

Seite 33 - :RESOlution Commands

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-27 1. :SYSTem:BEEPer Syntax :SYST

Seite 34

RIGOL Programming Guide for DM3000 II In This Manual This manual p

Seite 35

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-28 7. :SYSTem:CLOCk:DATE Syntax :SYSTem:CLOCk:DATE? :SYSTem:CLOCk:DATE <value>

Seite 36

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-29  SPACE: use space as the data

Seite 37

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-30 character string, for example, 03.12.00.03.09.00.02. 17. :SYSTem:TYPE? Syntax :S

Seite 38 - :SYSTem Commands

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-31 :UTILity Commands The commands

Seite 39

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-32 1. :UTILity:INTErface:LAN:DHCP Syntax :UTILity:INTErface:LAN:DHCP? :UTILity:INTEr

Seite 40

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-33 5. :UTILity:INTErface:LAN:MASK

Seite 41

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-34 :UTILity:INTErface:GPIB:ADDRess <value> Function Set the GPIB address of the

Seite 42

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-35 :TRIGger Commands The commands

Seite 43 - :UTILity Commands

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-36 1. :TRIGger:SOURce Syntax :TRIGger:SOURce? :TRIGger:SOURce {AUTO|SINGLE|EXT} Func

Seite 44 - <ip_address>

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-37 :TRIGger:AUTO:HOLD {ON|OFF|1|0}

Seite 45

RIGOL Programming Guide for

Seite 46

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-38 The query returns RISE or FALL. Default RISE 8. :TRIGger:VMComplete:POLAr Syntax

Seite 47 - :TRIGger Commands

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-39 :CALCulate Commands The comman

Seite 48

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-40 1. :CALCulate:FUNCtion Syntax :CALCulate:FUNCtion? :CALCulate:FUNCtion {NONE|NULL

Seite 49

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-41 2. :CALCulate:STATistic:MIN? S

Seite 50

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-42 Syntax :CALCulate:NULL:OFFSet? :CALCulate:NULL:OFFSet {<range>|MIN|MAX|DEF}

Seite 51 - :CALCulate Commands

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-43 Function Set the reference val

Seite 52

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-44 The query returns PASS or FAIL. Explanation Limit operation function must be enab

Seite 53

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-45 AC voltage 0 - 900 1 V DC cu

Seite 54 - <range>

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-46 :DATAlog Commands The commands are used to set the datalog parameters of the instr

Seite 55

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-47 1. :DATAlog:CONFigure? Syntax

Seite 57

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-48 Syntax :DATAlog:CONFigure:STARtmode:EXTern Function Set the start mode of the curr

Seite 58 - :DATAlog Commands

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-49 <range> Sample rate (n

Seite 59

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-50 returned. Example Query and return three data starting from number 2: :DATAlog:DA

Seite 60

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-51 :SCAN Commands The commands ar

Seite 61 - <value2>

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-52 1. :SCAN:PROJect? Syntax :SCAN:PROJect? Function Query the name of the scan proj

Seite 62

Chapter 2 Command System RIGOL Programming Guide for DM3000 2-53 Quency.  <Range>: the

Seite 63 - :SCAN Commands

RIGOL Chapter 2 Command System Programming Guide for DM3000 2-54 9. :SCAN:RUN Syntax :SCAN:RUN <Cycles> Function Set the number of cycles o

Seite 64 - <name>

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-1 Chapter 3 Commands Compatibility DM3000 series digital multimeter not on

Seite 65

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-2 Agilent Commands Compatibility The table below lists the Agilent commands s

Seite 66

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-3 {MINimum|MAXimum} CALCulate:L

Seite 67

Chapter 1 Programming Overview RIGOL Programming Guide for DM3000 1-1 Chapter 1 Programming Overview This chapter introduces how to program us

Seite 68

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-4 CONFigure:PERiod [{<range>|MIN|MAX|DEF}[,{<resolution>|MIN|MAX|D

Seite 69

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-5 current measurement. Note: th

Seite 70

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-6 [SENSe:]CAPacitance:RANGe:AUTO <mode> of capacitance measurement. [SE

Seite 71

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-7 does not support the NPLC val

Seite 72

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-8 [SENSe:]FREQuency:RANGe:LOWer {<filter>|MIN|MAX|DEF} 200. The “DEF” is

Seite 73

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-9 [SENSe:]FUNCtion[:ON] "&

Seite 74

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-10 [{<range>|MIN|MAX|DEF} [,{<resolution>|MIN|MAX|DEF}]] trigger p

Seite 75

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-11 <slope> can be POSitiv

Seite 76

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-12 {<range>|MIN|MAX|DEF} [SENSe:]RESistance:RESolution? [{MIN|MAX}] [SEN

Seite 77

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-13 [SENSe:]VOLTage[:DC]:IMPeda

Seite 78

RIGOL Chapter 1 Programming Overview Programming Guide for DM3000 1-

Seite 79

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-14 beeper is enabled. SYSTem:COMMunicate:ENABle? <interface> DM3000 only

Seite 80

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-15 SYSTem:COMMunicate:LAN:SMASk

Seite 81

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-16 Fluke Commands Compatibility The following table lists the Fluke commands s

Seite 82 - Fluke Commands Compatibility

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-17 <value> Reference Val

Seite 83

RIGOL Chapter 3 Commands Compatibility Programming Guide for DM3000 3-18 modes. If none of the modifier modes is selected, the query returns 0. REL

Seite 84

Chapter 3 Commands Compatibility RIGOL Programming Guide for DM3000 3-19 COMPCLR Exit the compare (CO

Seite 86

Appendix: Command Quick Reference RIGOL Programming Guide for DM3000 1 Appendix: Command Quick Reference *CLS 2-3 *IDN? 2-3 *RST 2-3 C CMDS

Seite 87

RIGOL Appendix: Command Quick Reference Programming Guide for DM3000 2 :MEASure:VOLTage:DC:RATIo? 2-9 :MEASure:VOLTage:DC:RATIo:DIGIt 2-10 :MEASur

Seite 88

Appendix: Command Quick Reference RIGOL Programming Guide for DM3000 3 :SYSTem:DISPlay:CONTrast 2-29 :S

Seite 89

Chapter 1 Programming Overview RIGOL Programming Guide for DM3000 1-3 Symbol Description 1. Col

Kommentare zu diesen Handbüchern

Keine Kommentare