Rigol DS2000A Series Spezifikationen Seite 185

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 390
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 184
2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-169
:MEASure:OVERshoot
Syntax 1
:MEASure:OVERshoot <chan>
Description 1
Enable the overshoot measurement function of the specified channel.
Syntax 2
:MEASure:OVERshoot? <chan>
Description 2
Enable the overshoot measurement function of the specified channel and return the measurement result.
Parameter
Name Type Range Default
<chan> Discrete {CHANnel1|CHANnel2|MATH} --
Return Format
The query returns the overshoot measurement result in scientific notation. When the measurement result
is invalid, the query returns 9.9e37.
Example
:MEASure:OVERshoot CHANnel1
:MEASure:OVERshoot? CHANnel1
You can use the following commands to enable the overshoot measurement function of the specified
channel and the statistic function of the measurement results as well as query the statistic maximum
value, minimum value, current value, average value and standard deviation of the overshoot
measurement results.
:MEASure:OVERshoot:SMAXimum
:MEASure:OVERshoot:SMINimum
:MEASure:OVERshoot:SCURrent
:MEASure:OVERshoot:SAVerage
:MEASure:OVERshoot:SDEViation
Seitenansicht 184
1 2 ... 180 181 182 183 184 185 186 187 188 189 190 ... 389 390

Kommentare zu diesen Handbüchern

Keine Kommentare