Rigol DS2000A Series Spezifikationen Seite 223

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 390
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 222
2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-207
:MEASure:MARea
Syntax 1
:MEASure:MARea <chan>
Description 1
Enable the area measurement function of the specified channel.
Syntax 2
:MEASure:MARea? <chan>
Description 2
Enable the area measurement function of the specified channel and return the measurement result (the
unit is Vs).
Parameter
Name Type Range Default
<chan> Discrete {CHANnel1|CHANnel2|MATH} --
Return Format
The query returns the area measurement result in scientific notation. When the measurement result is
invalid, the query returns 9.9e37.
Example
:MEASure:MARea CHANnel1
:MEASure:MARea? CHANnel1
You can use the following commands to enable the area measurement function of the specified channel
and the statistic function of the measurement results as well as query the statistic maximum value,
minimum value, current value, average value and standard deviation of the area measurement results.
:MEASure:MARea:SMAXimum
:MEASure:MARea:SMINimum
:MEASure:MARea:SCURrent
:MEASure:MARea:SAVerage
:MEASure:MARea:SDEViation
Seitenansicht 222
1 2 ... 218 219 220 221 222 223 224 225 226 227 228 ... 389 390

Kommentare zu diesen Handbüchern

Keine Kommentare