Rigol DM3058 Spezifikationen Seite 43

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 264
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 42
RIGOL
Programming Guide for DM3058
3-17
:measure:current:ACMAX or :measure:current:AC3
16. :measure:current:AC:range?
Command Format:
:measure:current:AC:range?
Function:
The command queries AC current range.
Explanation:
Before sending the command, please enable AC current measuring function.
Return Format:
The query returns the parameter related to current range : 0, 1, 2 or 3 (see Table
3-4).
17. :measure:resistance?
Command Format:
:measure:resistance?
Function:
The commad queries 2-wire resistance.
Explanation:
This command is invalide for Dual Display.
Return Format:
The query returns the current resistance in the form of 8.366031e-05, and unit is
Ω.
18. :measure:resistance
Command Format:
:measure:resistance{<range>|MIN|MAX|DEF}